Series-C I/O modules are constructed to support normal field failures, wiring errors and conditions such as a shorted wire. All Series-C IOTAs contain at least one fuse that provides protection for catastrophic errors in the IOTA, IOM and other elements of the Series-C system. In normal operation as well as many abnormal operations, the fuse element should not blow.
INQUIRE NOW
Products Name: 14507566-001 Honeywell Input module Brand new
PRODUCT DESCRIPTION
Brand: Honeywell
Model number:14507566-001
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.5kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service : Professional Sales provides 24 hours /7 days online service
14507566-001 Honeywell Input module Brand new
Description:
Standard 2-wire transmitter l Can use any of the 16 channels.
l No custom wiring required.
l No jumper cuts required.
Standard self-powered
transmitter
l Can use any of the 16 channels.
l No custom wiring required.
l No jumper cuts required.
Self-powered transmitter with
loop power (system ground)
l Can use any of the 16 channels.
l Custom wiring is required for channels 1-12: you must find a
screw terminal at Series C ground for one leg of the
transmitter.
l No jumper cuts required
Self-powered transmitter with
loop power (device ground)
l Cannot use channels 1-12.
l Only use channels 13-16.
Self-powered 3-wire
transmitter
(system ground)
l Can use any of the 16 channels.
l Custom wiring is required for channels 1-12: you must find a
screw terminal at Series C ground for one leg of the
transmitter.
l No jumper cuts required
Voltage Input (system ground) l Can use any of the 16 channels.
l Custom wiring is required for channels 1-12: you must find a
screw terminal at Series C ground for one leg of the
transducer.
l You must cut the jumper associated with the range spool.
Voltage Input (device ground) l Cannot use channels 1-12.
l Only use channels 13-16.
NOTE
If multiple instruments need a ground reference the four positions of TB2 can serve as
those ground points (assuming the JP17-JP20) jumpers are intact. If more than four
grounding screws are needed then a custom wire from TB2 to a separate terminal
block can allow for more grounding screw positions.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
TC-IXL062
TC-KIOL02
TCM4351A
TCM4351B
TC-OAH061
TC-ODD32
TC-ODX161
TCP202A
TC-RPFM01
TCSECE300R2
TCSEK3MR10
TC-TG-F1C3
TC-XXXXX2
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020