The maximum allowable field wiring resistance between the transmitter and the IOTA connection terminal is dependent upon the voltage requirement of the transmitter. The formula for calculating the maximum wiring resistance for the Series C UIO channel used as an analog input is given by the following equation.
INQUIRE NOW
Products Name: 30731565-002 Honeywell Input module Brand new
PRODUCT DESCRIPTION
Brand: Honeywell
Model number:30731565-002
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.5kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service : Professional Sales provides 24 hours /7 days online service
30731565-002 Honeywell Input module Brand new
Description:
The following list summarizes the key points on relays.
l Relay K1 (FC1) is associated with CH7 only.
l Relay K2 (FC2) is associated with CH8 only.
l User load can be connected in either leg (or both legs) of the relay path provided polarity is
observed.
l Each relay contains a top mounted LED that illuminates green to indicate that the relay is in
the ON state (conducting). The LED is extinguished to indicate the relay is in the OFF state
(non-conducting).
l The IOTA relay connections are rated for 1.5 Adc, 60 Vdc maximum.
l The fuses in relays K1 and K2 are user replaceable (5 x 20 mm, 2.5A /250V, time lag).
l The relays K1 and K2 are electrically isolated from each other, from system power and ground
and from chassis (cabinet) ground.
l Relays K1 and K2 are replaceable by ordering Honeywell part number 51190516-134.
Figure 6.12 Fast Cutoff relay wiring diagram
- 230 -
Chapter 6 - Series C PIM connectivity
Chapter 6 - Series C PIM connectivity
6.8 About enabling pulse proving in PIM
You must use Control Builder to select the stream to be proved (only one per PIM). This action
connects the good pulses from the selected stream to the Prover Pulse Bus. For each good pulse
from the selected stream, a 20 us wide positive going pulse is output on the PIM Prover Bus. The
tri-state output of the Prover Pulse Bus allows for multiple Series C Prover Pulse outputs to be
connected in parallel to a single ST102 (or other hardware) allowing for larger installations which
have more meter streams for a single meter prover.
Only channel pairs configured in dual configuration can provide a source of good pulses for prover
output.
Refer to the section Enabling pulse proving in Pulse Input Module for more information.
For proper operation of the Prover Pulse Bus, a resistor must be connected to TB4 as shown in the
following diagram.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
TC-IXL062
TC-KIOL02
TCM4351A
TCM4351B
TC-OAH061
TC-ODD32
TC-ODX161
TCP202A
TC-RPFM01
TCSECE300R2
TCSEK3MR10
TC-TG-F1C3
TC-XXXXX2
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020