Because the maximum transmitter output level is -7 dB, and the maximum receiver input level is -10 dB, the receiver may be overdriven on a short link and may require a 3 dB attenuator. Connector allowances for the transmitter and receiver are included in the above power declaration.
INQUIRE NOW
Products Name: 51109919-100 Honeywell Input module Brand new
PRODUCT DESCRIPTION
Brand: Honeywell
Model number:51109919-100
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.5kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service : Professional Sales provides 24 hours /7 days online service
51109919-100 Honeywell Input module Brand new
Description:
ATTENTION
When MODE is ' ;Manual,' OPBIAS is not used (because OP is not calculated). Consequently,
when MODE changes to Manual, OPBIAS is not recomputed.
l You can store to OPBIAS only if the function block is inactive or MODE is 'Manual.' Hence,
prevent a bump in OP is prevented when the bias is changed.
l When you store values to OPBIAS, the following occurs.
o Total bias (OPBIAS) and fixed bias (OPBIAS.FIX) are both set to a new value.
l There are no limit checks applied when you store the OPBIAS. However, after the bias is added
to the calculated variable (CV), the result is compared against the OP limits and clamped, if
necessary.
l You can store to OPBIAS.FIX only if the function block is inactive and SVP_REGCTL is
configured with the control algorithm equation as 'E.' When you store to OPBIAS.FIX, the
following occurs.
o Total bias (OPBIAS) and fixed bias (OPBIAS.FIX) are both set to a new value.
10.25.9 Time-out monitoring
If MODE is set to 'Cascade,' SVP_REGCTL channel monitors its SP input value (that is, primary
input) for time-out. If a valid SP value is not received within the predefined time, the SVP_REGCTL
channel invokes time-out processing. The time-out time (in seconds) is specified by TMOUTTIME.
l Enable time-out monitoring by setting TMOUTTIME to a non-zero value.
l Disable time-out monitoring by setting TMOUTTIME to zero.
10.25.10 Time-out processing
A time-out can occur for several reasons communication error, inactivation of primary block, and
so on. If an input times-out, SVP_REGCTL channel performs setting a time-out flag (TMOUTFL),
requesting the primary block to initialize, and shedding the SVP_REGCTL channel to a predefined
mode (TMOUTMODE).
If MODE is set to 'Cascade' and the SP time-out, the SVP_REGCTL channel performs the following:
l Sets a time-out flag (TMOUTFL).
l Requests the primary to initialize.
ATTENTION
In SVP_REGCTL channel, the primary can be an ENHGENLIN block and AUXILIARY
Function block from C300-20mS CEE Controller and no initialization happens to it.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
TC-IXL062
TC-KIOL02
TCM4351A
TCM4351B
TC-OAH061
TC-ODD32
TC-ODX161
TCP202A
TC-RPFM01
TCSECE300R2
TCSEK3MR10
TC-TG-F1C3
TC-XXXXX2
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020