The controller can be mounted in any orientation. 

Ventilation openings are designed into the cover to allow 

proper heat dissipation, regardless of the mounting 

orientation.


INQUIRE NOW

Products Name: 51401547-100 Honeywell Input module Brand new

PRODUCT DESCRIPTION

Brand:   Honeywell  

Model number:51401547-100

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.5kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service Professional Sales provides 24 hours /7 days online service

51401547-100  Honeywell    Input  module  Brand  new 

Description:

The most common cause for the DO over-current is a failure in the field there is a minor

probability that the IOM itself might be the cause of the problem. Given this, it is a common

behavior for Series C IOMs to always switchover in an attempt to localize the fault.

TIP

Note that the Primary switchover in most cases is done before actually experiencing the

over current condition.

If the cause for the DO over-current is a failure in the field, then the new Primary will see the same

output miscompare problem, and react like a non-redundant module would - it will:

l Detect the output miscompare generate Soft Failure 23 - Failure in OP circuit/field wiring

detected by AO/DO.

l Detect the over current and generate Soft Failure 180 - Output Short Circuit Detected

l Set the output to unpowered.

l Shed Mode to Manual control.

l Shed ModeAttr to Operator.

You should expect to see:

l One Soft Failure posted from the former Primary:

l Soft Failure 23 - Failure in OP circuit/field wiring detected by AO/DO

l A IOM Failover event

The following are likely if the fault was in the field:

o Two Soft Failures posted by the new Primary:

Soft Failure 23 - Failure in OP circuit/field wiring detected by AO/DO Soft Failure 180 -

Output Short Circuit Detected

o The output unpowered

o The channel in Manual mode

o The former Primary's output miscompare Soft Failure will Return To Normal once

both modules synchronize.

10.16.3 Electronic Short-Circuit Fault Recovery

To return the channel to normal operation the shorted device or shorted wiring must be corrected.

10.16.4 To clear the short-circuit fault:

CAUTION

Immediately after the IOM detects the fault and the DO Channel is set to OFF, it should be

safe to perform maintenance action.

Once the DO channel is set ON, no maintenance action can occur.


image.png

Shipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service