Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / Honeywell / 621-2150R Honeywell

621-2150R Honeywell

Brand:   Honeywell  

Model number:621-2150R

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.5kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

621-2150R   Honeywell

INQUIRE NOW

Products Name: 621-2150R Honeywell

PRODUCT DESCRIPTION

In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The information and specifications in this document are subject to change without notice.

Description:

Configuring the setpoint ramp

You can configure a single setpoint ramp to occur between the current local setpoint and a final local 

setpoint over a time interval of from 1 to 255 minutes. You can RUN or HOLD the ramp at any time.

Procedure

75HTable 5-17 lists the procedure for configuring the Setpoint Ramp 1 or 2 parameters. The procedure for 

Setpoint Program is in Section 6 – Setpoint Ramp/Soak Programming Option.

Table 5-17 Procedure for configuring a single setpoint ramp

Step Operation Press Action/Result

1 Select SP RAMP 1 or 

SP RAMP 2 Set Up 

group

SET

UP

Until you see:

Upper Display: SET UP

Lower Display: SP RAMP X

X = 1 or 2

2 Select the Setpoint Ramp 

function

FUNC Until you see:

Upper Display: DISABL

Lower Display: SP RAMP X

3 Enable Setpoint Ramp ▲ Until you see:

Upper Display: ENABLE

Lower Display: SP RAMP X

NOTE: You cannot change the current local setpoint if 

the setpoint ramp function is enabled. Make sure SP 

PROG is disabled.

4 Set the Ramp Time FUNC Until you see:

Upper Display: The ramp time in minutes

Lower Display: TIME MIN

▲ or ▼ Change the upper display value to the number of 

minutes in which you want the final setpoint to be 

reached.

Setting Range = 1 to 255 minutes

NOTE: Entering “0” implies an immediate step change 

to the final SP.

5 Set the Final Setpoint 

value

FUNC Upper Display: The final setpoint value

Lower Display: FINAL SP

6 ▲ or ▼ Change the upper display value to the desired final 

setpoint value.

Setting Range = within the setpoint limits

51454472-175 8C-PDODA1   Honeywell

Shipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

TC-IXL062

TC-KIOL02

TCM4351A

TCM4351B

TC-OAH061

TC-ODD32

TC-ODX161

TCP202A

TC-RPFM01

TCSECE300R2

TCSEK3MR10

TC-TG-F1C3

TC-XXXXX2


image.png