Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / Honeywell / 82408470-001 Honeywell Input module Brand new

82408470-001 Honeywell Input module Brand new

Each controller is programmable because the user chooses which function blocks to use and how to connect 

them. It is configurable because each Function Block has 

user-defined behavior.


INQUIRE NOW

Products Name: 82408470-001 Honeywell Input module Brand new

PRODUCT DESCRIPTION

Brand:   Honeywell  

Model number:82408470-001

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.5kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service Professional Sales provides 24 hours /7 days online service

82408470-001  Honeywell   Input module Brand new     

Description:

AC IN The LED turns ON when the AC input voltage is sufficient to start the unit. This is

guaranteed to occur when the input voltage has risen to 85 Vac, but it could occur

at a lower voltage, depending on output loading and unit-to-unit variations. Once

the unit starts, the LED remains ON through the entire AC input voltage range.

The LED will turn OFF at the point where the power supply shuts down. For a fully

loaded supply, this is guaranteed not to occur until the input voltage descends

below 85 Vac. This voltage can be considerably lower, if the unit is lightly loaded

and depending on unit-to-unit variations. The unit does not shut down when the

AC input range is exceeded unless there is a failure in the power supply.

Status The LED turns ON when output voltage is within the operating range. The LED

turns OFF when the DC voltage is increased to above 26.4 Vdc and the power

supply shuts down due to an over-voltage condition. (Based on manufacturer's

- 567 -

Chapter 17 - Series C Power Sub-System Connections and Alarm Indications

Chapter 17 - Series C Power Sub-System Connections and Alarm Indications

LED Name Functional Description

tests, the actual data range for over-voltage is 26.4 to 30 Vdc.) The LED turns OFF

during output overload, which is reached when the load is increased to over 26 A

and results in the unit shutting down.

Main Battery Backup Charger/Regulator/Monitor Indicators

Status The LED turns ON when both the input and battery voltages are within operating

range. The LED will remain ON until the battery reaches the Low-Voltage Drop-out

point (32 Vdc) and the unit turns OFF along with the LED (output will still be

regulated at 25 Vdc during battery discharge). The LED turns OFF when the

battery voltage is above 45.5 Vdc. (Based on manufacturer's tests, the actual data

range for over-voltage is 45.5 to 48.5 Vdc.)

Battery

Charged

The LED operation is based on both battery charge voltage and battery charge

current. The battery charge voltage must be above 40 Vdc and the battery charge

current must be below 1 A for the LED to be ON. If both of these conditions are not

met, the LED will be OFF


image.png

Shipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

TC-IXL062

TC-KIOL02

TCM4351A

TCM4351B

TC-OAH061

TC-ODD32

TC-ODX161

TCP202A

TC-RPFM01

TCSECE300R2

TCSEK3MR10

TC-TG-F1C3

TC-XXXXX2