82408667-005 Honeywell Power module Brand new

If multiple instruments need a ground reference the four positions of TB2 can serve as those ground points (assuming the JP17-JP20) jumpers are intact. If more than four grounding screws are needed then a custom wire from TB2 to a separate terminal block can allow for more grounding screw positions.

INQUIRE NOW

Products Name: 82408667-005 Honeywell Power module Brand new

PRODUCT DESCRIPTION

Brand:   Honeywell  

Model number:82408667-005

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.5kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service Professional Sales provides 24 hours /7 days online service

82408667-005   Honeywell   Power module Brand new 

Description:

MS/TP MAC Address

The MS/TP MAC address for each device must be set to a 

unique value in the range of 0-127 on an MS/TP network 

segment. DIP switches on the Spyder BACnet controller 

are used to set the controller's MAC address.

Device Instance Number

The Device Instance Number must be unique across the 

entire BACnet system network because it is used to 

uniquely identify the BACnet devices. It may be used to 

conveniently identify the BACnet device from other 

devices during installation. The Spyder BACnet 

Controllers Device Instance Number is automatically set 

when it is added to a WEBStation-AX project. The Device 

Instance Number can be changed by the user, which may 

be necessary when integrating with a third party or when 

attempting to replace an existing controller and it is 

desired to maintain the existing Device Instance Number.

NOTE: For complete instructions on how to set the 

MS/TP MAC address or set the Device Instance 

Number refer to the Installation Instructions, 

form 62-0310.

Termination Resistors

Matched terminating resistors are required at each end of 

a segment bus wired across (+) and (-). Use matched 

precision resistors rated 1/4W ±1% / 80 - 130 Ohms. 

Ideally, the value of the terminating resistors should 

match the rated characteristic impedance of the installed 

cable. For example, if the installed MS/TP cable has a a 

listed characteristic impedance of 120 Ohm, install 120 

Ohm matched precision resistors.

NOTE: The controller does not provide any network biasing.

Shield Terminating

Following proper MS/TP cabling shield grounding 

procedures is important to minimize the risk of 

communication problems and equipment damage caused 

by capacitive coupling. Capacitive coupling is caused by 

placing MS/TP cabling close to lines carrying higher 

voltage. The shield should be grounded on only one end of 

the MS/TP segment (typically the router end). Tie the 

shield through using the SHLD (terminal 4) on the Spyder 

BACnet Controller.


image.png

Shipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

TC-IXL062

TC-KIOL02

TCM4351A

TCM4351B

TC-OAH061

TC-ODD32

TC-ODX161

TCP202A

TC-RPFM01

TCSECE300R2

TCSEK3MR10

TC-TG-F1C3

TC-XXXXX2