INQUIRE NOW
Products Name: 900TCK-0001 Honeywell Analog Input Module
PRODUCT DESCRIPTION
Brand: Honeywell
Model number: 900TCK-0001
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.24kg
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Description:
Honeywell offers multiple ExperionPKS controllers, ranging from embedded controller platforms with dedicated IO hardware
to PC based control environments for supervisory control tasks or simulation. They all support one or more different network
types to integrate the controllers with the ExperionPKS Server. They share a common Control Execution Environment (CEE)
software infrastructure and a common builder tool. Together with the different station types, they form the ExperionPKS
system. This specifications document provides details specifically related to the ExperionPKS C300 controller.
Note 2 – Exchange Peer-Peer does not count against this limit.
Note 3 – There are 31 connections reserved for Peer-Peer in the C300. 1 connection is reserved for Internal C300 useonly, leaving 30 connections available for User P2P configurations.
Note 4 – 1 DHRIO Module only counts as 1 Target Device even when communicating with multiple PLCs on either of
the two DH+ networks per DHRIO.
Note 5 – Redundant devices that use two PCDI Master blocks count as only one device. Secondary test messages do
count in the messages per second for C300 performance estimation.
Note 6 – PCDI impact on C300 performance can be estimated with the C300 Performance Model worksheet (see
section 2.3.4); important factors are number of PCDI Master blocks, number of PCDI Request block messages
per second, and message data size.
Note 7 – Incoming peer data benefits from the RBE (Report by Exception) comparisons done at the data source, so
only changed parameters contribute to the incoming PPS load.
Note 8 – Outgoing peer data capacity is defined/measured before the RBE (Report by Exception) comparisons are
done, so all parameters requested as peer data contribute to the outgoing PPS load, whether they are
changing or not and sent over the network or not.
Note 9 – CDA Peer connection to a redundant SM consumes 2 PCUs.
Note 10 – PCDI Licenses per Server is limited to 256 total PCDI Device Blocks for all C300s and ACEs combined.
Note 11 - Float, integer, or BOOLEAN values configured constitute one parameter
Note 12- Number of PIOMB blocks that can be instantiated or loaded to the C300 is limited by the C300 CEE memory,
and CPU.
Note 13- Overlap between controller CDA peer and display responder requests was removed for C300v2 and C300E in
R510 release to prevent loss of peer communication during high display subscriptions from process
operational displays.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
TC-IXL062
TC-KIOL02
TCM4351A
TCM4351B
TC-OAH061
TC-ODD32
TC-ODX161
TCP202A
TC-RPFM01
TCSECE300R2
TCSEK3MR10
TC-TG-F1C3
TC-XXXXX2
TDM1.2-050-300-W1-000
TK-FFIF01
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020