Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / Honeywell / EC7850A1122 Honeywell Central control module Brand new

EC7850A1122 Honeywell Central control module Brand new

The maximum allowable field wiring resistance between the transmitter and the IOTA connection terminal is dependent upon the voltage requirement of the transmitter. The formula for calculating the maximum wiring resistance for the Series C UIO channel used as an analog input is given by the following equation.

INQUIRE NOW

Products Name: EC7850A1122 Honeywell Central control module Brand new

PRODUCT DESCRIPTION

Brand:   Honeywell  

Model number:EC7850A1122  

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.5kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service Professional Sales provides 24 hours /7 days online service

EC7850A1122   Honeywell    Central control module Brand new 

Description:

Lower Display

Prompt

Upper Display

Range of Setting or Selection

Parameter Definition

INn LO

(n = 1 or 2)

–999.9 to 9999.

or

–999 to 9999

in Engineering units

INPUT LOW RANGE VALUE in engineering units is 

displayed for all inputs but can only be configured for 

linear or square root transmitter characterization.

· Otherwise, this is a read-only display of the low range 

value for the selected T/C or RTD input including 

transmitter characterization, if applicable.

· Scale the input signal to the display value you want 

for 0%. See example on previous page. The control 

setpoint for Input will be limited by the range of units 

selected here.

CUTOFF n

(n = 1 or 2)

0 to 100% of Input Range LOW FLOW CUTOFF—Lets you set a value in percent 

of range below which the applicable totalizer does not 

increment.

ATTENTION

Prompt appears only if totalizer option 

is present in the recorder.

BIAS n n = 1 – 2 –999.9 to 9999. INPUT COMPENSATION — used to compensate the 

input for drift of an input value due to deterioration of a 

sensor, or some other cause; select the value you want 

on the input.

FILTER n

(n = 1 or 2)

0 to 120 seconds

No filter = 0

FILTER FOR INPUT — a software digital filter is 

provided for the input to smooth the input signal. You 

can configure the first order lag time constant from 1 to 

120 seconds. If you do not want filtering, enter 0.

BURNOUT

NONE

UP

DOWN

BURNOUT PROTECTION (SENSOR BREAK) provides 

most input types with upscale or downscale protection if 

the input fails.

· Not available for inputs 0-5V, 0-10V, or 4-20 mA.

NO BURNOUT — Failsafe output applied for failed 

input.

UPSCALE BURNOUT will make the indicated PV signal 

increase when a sensor fails, and flash the upper 

display.

DOWNSCALE BURNOUT will make the indicated PV 

signal decrease when a sensor fails, and flash the upper

display.

NOTE: For no Burnout (that is, “None”) to function 

properly on a linear input, there must be a dropping 

resistor directly across the input terminals (that is, not 

remote), then the unit can detect the “zero” voltage that 

occurs when the 4-20 mA line is opened.

EMISSIV .01 to 1.00 EMISSIVITY is a correction factor applied to the 

Radiamatic input signal that is the ratio of the actual 

energy emitted from the target to the energy which 

would be emitted if the target were a perfect radiator. 

Available only for “Radiamatic” inputs.


C7024E-1001   Honeywell    Central control module Brand new

Shipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

TC-IXL062

TC-KIOL02

TCM4351A

TCM4351B

TC-OAH061

TC-ODD32

TC-ODX161

TCP202A

TC-RPFM01

TCSECE300R2

TCSEK3MR10

TC-TG-F1C3

TC-XXXXX2


image.png