Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / Honeywell / K4LCN-16 51403519-160 Honeywell

K4LCN-16 51403519-160 Honeywell

Brand:   Honeywell  

Model number:K4LCN-16 51403519-160 

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.5kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

K4LCN-16 51403519-160   Honeywell

INQUIRE NOW

Products Name: K4LCN-16 51403519-160 Honeywell

PRODUCT DESCRIPTION

Because the maximum transmitter output level is -7 dB, and the maximum receiver input level is -10 dB, the receiver may be overdriven on a short link and may require a 3 dB attenuator. Connector allowances for the transmitter and receiver are included in the above power declaration.

Description:

Introduction

Segment events are used to activate relays by means of alarms. There are six alarms and six corresponding 

relays. Alarm 1 controls Relay 1, Alarm 2 controls Relay 2, etc. When the setpoint program reaches the 

segment, the segment event triggers the alarm which triggers the relay. The relay stays on for the duration 

of the segment. There are no alarm conditions to be satisfied, that is, when the event goes on the alarm 

goes on.

How to trigger a relay with a segment event

1. Program the segment event with the alarm corresponding with the desired relay.

2. Program that alarm as type EVENT. It is not necessary to program any alarm parameters other than the 

alarm type.

Do not program other functions that have higher priority control of the relay. See During alarm conditions 

an alarm will deenergize its associated relay unless a higher priority function has been configured for that 

relay. See Table 3-11. If you want the alarm to control the relay, do not configure a higher priority 

function.

3. Table 3-11.

Setpoint Program Event group prompts

Table 6-6 lists all the function prompts in the Setpoint Program Event setup group and their definitions.

Table 6-6 Setpoint program event group definitions

Lower Display

Prompt

Upper Display

Range of Setting or Selection

Parameter Definition

SEGx EV

 (x = 1-36)

NONE

ALARM1, ALARM2, ALARM3, 

ALARM4, ALARM5, ALARM6

Configured event will be active during the segment. All 

others will be inactive.

Example of how a segment event works

For example, to have Segment 1 energize Relay 1:

· Program SEG1 EV as ALARM1.

· Program A1S1TYPE or A1S2TYPE as EVENT.

· Do not program the Timer function Relay 1; namely, Timer.

For alarm programming information, see section 4.10.

CC-PDOB01 51405043-175   Honeywell

Shipping Port: China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

TC-IXL062

TC-KIOL02

TCM4351A

TCM4351B

TC-OAH061

TC-ODD32

TC-ODX161

TCP202A

TC-RPFM01

TCSECE300R2

TCSEK3MR10

TC-TG-F1C3

TC-XXXXX2


image.png