Description:

Defines the maximum size of the first output step in the autotuning process. Autotune adjusts

the output step magnitude according to the process noise and response to provide a reliable

measurement of the process characteristics with the minimum disturbance of the process. The

maximum setting provides the largest output step possible from the current output value.

Dynamics Used to configure Autotune to give optimum results according to the type of process being

controlled.

Normal Determines if derivative control is required automatically and calculates the control settings

accordingly.

Deadtime Sets the proportional and integral terms to give optimum control for the deadtime process

(higher proportional band [lower gain] and shorter integration time).

PI Used for processes where it is known that derivative control is not required.

Reset If the controller is transferred to another process or duty, Autotune must be reset. The current

PID (see page 32) settings are retained but the internal process data is cleared ready for a

completely new process with different characteristics.

PID The controller’s PID (proportional, integral and derivative control) settings can be commissioned

using the Autotune (see page 30) function and / or they can be adjusted manually.

Proportional Band 1 Set as % of engineering range.

Integral Time 1 Set in seconds per repeat. To turn integral action off, set to 0 or 10000 s.

Derivative Time 1 Set in seconds.

SDCS-AMC-DC-2   ABB  Feeder Protection and Control

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

DSTK165

TB805

PM864AK01

TU811V1

SDCS-CON-1

AINT-14C

1SNA631025R1400 BOM-16-B

SPA-ZC21MB       

DSQC639

DSCS-PIN-205B 

PM866AK01

SDCS-PIN-205B COATED

IMMFP02

Pcd231b101