Description:
The procedures in this section assume you have prepared your panel
and understand how to bond your system. For installation instructions
regarding other equipment and accessories, refer to the instructions
that came with each of the accessories for their specific requirements.
To mount your Ultra3000 drive:
1. Layout the position for the Ultra3000 and accessories in the
enclosure (refer to Establishing Noise Zones for panel layout
recommendations). Mounting hole dimensions for the Ultra3000
are shown in Appendix A.
2. Attach the Ultra3000 to the cabinet, first using the upper mounting
slots of the drive and then the lower. The recommended mounting
hardware is M5 metric (1/4-20) or #10 MS bolts. Observe bonding
techniques as described in HF Bonding Your System.
3. Tighten all mounting fasteners.
This drive contains ESD (Electrostatic Discharge)
sensitive parts and assemblies. You are required to
follow static control precautions when you install,
test, service, or repair this assembly. If you do not
follow ESD control procedures, components can be
damaged. If you are not familiar with static control
procedures, refer to Allen-Bradley publication
8000-4.5.2, Guarding Against Electrostatic Damage
or any other applicable ESD Protection Handbook.
IMPORTANT To improve the bond between the Ultra3000 and
subpanel, construct your subpanel out of zinc
plated (paint-free) steelBuilding Your Own Cables
When building your own cables, follow the guidelines listed below.
• Connect the cable shield to the connector shells on both ends of
the cable for a complete 360° connection.
• Use a twisted pair cable whenever possible, twisting differential
signals with each other, and single-ended signals with the
appropriate ground return.
Refer to Appendix C for drive connector kit catalog numbers.
Routing Power and Signal Wiring
Be aware that when you route power and signal wiring on a machine
or system, radiated noise from nearby relays, transformers, and other
electronic drives, can be induced into motor or encoder feedback,
communications, or other sensitive low voltage signals. This can cause
system faults and communication problems.
Refer to Chapter 1 for examples of routing high and low voltage
cables in wireways. Refer to System Design for Control of Electrical
Noise (publication GMC-RM001x-EN-P) for more information.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
20F11ND027AA0NNNNN
2711-T5A2L1
2711PC-T6M20D
1794-IR8
1756-RM2
1794-OB32P
1794-IE12
22B-D2P3N104
1794-OE12
1794-IRT8XT
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020