Description:

Enhancements with Revision 2.013 

Cat. No. Enhancement

2094-EN02D-M01-S0 and 

2094-EN02D-M01-S1

The default gateway is configured to a default address when the IP address is assigned with the rotary switches.

The drive can detect reversed wiring of the encoder's sine and cosine signals when running a commutation test.

Adds the Torque Prove feature: 

• The purpose of Torque Prove is to verify that the drive is able to produce torque at the motor prior to releasing the motor brake. The feature works by 

applying current to motor phases in such a way that it can verify all three power phases are connected. 

• You must enable Torque Prove by sending a Message instruction to the drive’s Motion Device Axis object (Class Hex 42, Attribute Number Hex 44C). 

Bit 0 of this attribute controls Torque Prove Enable. Setting this bit 0 to 1 enables Torque Prove. Setting bit 0 to 0 disables Torque Prove. 

The remaining bits of this attribute are reserved. 

• When Torque Prove is enabled, the test is performed each time the drive transitions to ‘Servo On’. If Torque Prove fails, the drive issues a Torque Prove 

fault (M18) and does not release the brake or enable. 

• The Torque Prove feature is not able to detect all possible motor wiring problems. Complete the appropriate Hookup tests to verify proper motor 

wiring. Torque Prove is primarily meant to detect a loose or broken motor connection. 

• The Torque Prove feature is not supported for motors without a brake. Enabling the torque prove feature on a motor without a brake results in 

unintended motion when the drive transitions to ‘Servo On’.

The drive can run passive hookup tests without bus power or when Safe-off is active. 

Single-turn absolute encoders now support use as incremental feedback devices. 

2904-EN02D-M01-S1 Allen Bradley  Digital Input Module

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

20F11ND027AA0NNNNN

2711-T5A2L1

2711PC-T6M20D

1794-IR8

1756-RM2

1794-OB32P

1794-IE12

22B-D2P3N104

1794-OE12