When installing a new battery, when there currently is no battery installed, the battery must be installed while the CPU has power. Failing to follow this procedure could result in the CPU not powering up. If a battery is installed while power is off (and there was no battery previously installed), and the CPU fails to power up, simply remove the battery, power cycle the CPU and then install the battery.
INQUIRE NOW
Products Name: A02B-0118-B005 GE Controller module Brand new
PRODUCT DESCRIPTION
Brand:GE
Model number:A02B-0118-B005
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.27kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
A02B-0118-B005 GE Controller module Brand new
Each circuit on an 4 Input/2 Output Analog Block can accept or
provide signals in one of five analog ranges:
0-10 volts DC
-10 volts DC to +10 volts DC
-5 volts DC to +5 volts DC
0-5 volts DC
4-20 mA/1-5 volts DC
This flexibility allows these blocks to be used with a wide variety of
analog input and output devices. The block’s internal power supply
drives current mode output loads up to 300 Ohms each. For loads
up to 2K Ohms, an external 24 or 48 VDC power supply can be
used.
Configurable block features include:
Independent scaling for each input and output.
Fault reports to the host can be enabled or disabled for each
input and output.
Selectable Input Filter Time up to 1024ms.
Each input can operate in normal analog input mode, or report
only its alarm status.
Low and high alarm limits for each input, in either normal input
mode or alarm input mode.
Powerup default values for each output.
Each output can be configured to hold last state or default if
CPU communications are lost.
Input Low Alarm and High Alarm detection.
Open Wire detection on current mode inputs.
Input Underrange or Overrange.
Output Underrange or Overrange.
Discrete Input
Modules(1) IC200MDL140 Input 120 VAC (1 Group of 8) 8
Points IC200MDL631 Input 125 VDC Pos/Neg Logic
Isolated 8 Points
IC200MDL141 Input 240 VAC (1 Group of 8) 8
Points IC200MDL632 Input 125 VDC Pos/Neg Logic
Isolated 16 Points
IC200MDL143 Input 120 VAC Isolated 8 Points IC200MDL635 Input 48 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL144 Input 240 VAC Isolated 4 Points IC200MDL636 Input 48 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL240 Input 120 VAC (2 Groups of 8) 16
Points IC200MDL640 Input 24 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL241 Input 240 VAC (2 Groups of 8) 16
Points IC200MDL643 Input 5/12 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL243 Input 120 VAC Isolated 16 Points IC200MDL644 Input 5/12 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL244 Input 240 VAC Isolated 8 Points IC200MDL650 Input 24 VDC Pos/Neg Logic (4
Groups of 8) 32 Points