This section has special installation instructions for High-density Terminal Blocks. See chapter 2 for general installation information.
INQUIRE NOW
Products Name: A02B-0311-B500 GE Power module Brand new
PRODUCT DESCRIPTION
Brand:GE
Model number:A02B-0311-B500
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.27kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
A02B-0311-B500 GE Power module Brand new
BIT_SEQ function block DIR parameter The BIT_SEQ Function Block should require the user to flow
BOOLEAN logic into the DIR parameter, but currently does not. If no
DIR parameter is present, the BIT_SEQ will increment by default.
WinLoader may stop operating On computers running Windows 2000 and using some versions of
Symantec Antivirus protection, WinLoader will fail if used in advanced
mode. Recovery requires cycling the computer's power.
Logic and HWC not equal after power cycle If the Hardware Config from Target 1, with Logic/Configuration Powerup Source and Data Source both set to “Always from Flash,” is stored
in Flash, then Logic and Hardware Config from Target 2, with
Logic/Configuration Power-up Source both set to “Always from RAM,”
is stored to RAM and there is a good battery, then when power is
cycled the programmer may show that Logic and Hardware Config are
not equal. The remedy is to clear Flash and then store the Logic and
Hardware Config from Target 2.
WinLoader does not detect PC COM port in
use when upgrading PACSystems CPU
WinLoader does not detect if a PC's COM port is already in use when
attempting to connect to a PACSystems CPU to perform a firmware
upgrade. If the port is already in use it displays the status "trying to
connect" followed by "waiting for target." To proceed with the upgrade,
press the "abort" button and disconnect the other application that is
using the COM port.
WinLoader does not display error when it
cannot connect serially with PACS CPU
WinLoader does not display an error message if it cannot connect to
the PACS CPU when attempting to connect to a PACSystems CPU to
perform a firmware upgrade. This occurs if the cable is physically not
connected to the CPU or if the CPU's serial port is not configured for
the same baud as WinLoader. In this case Winloader displays the
status "trying to connect" followed by "waiting for target." To proceed
with the upgrade, press the "abort" button and correct the cable or
baud rate setting
Discrete Input
Modules(1) IC200MDL140 Input 120 VAC (1 Group of 8) 8
Points IC200MDL631 Input 125 VDC Pos/Neg Logic
Isolated 8 Points
IC200MDL141 Input 240 VAC (1 Group of 8) 8
Points IC200MDL632 Input 125 VDC Pos/Neg Logic
Isolated 16 Points
IC200MDL143 Input 120 VAC Isolated 8 Points IC200MDL635 Input 48 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL144 Input 240 VAC Isolated 4 Points IC200MDL636 Input 48 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL240 Input 120 VAC (2 Groups of 8) 16
Points IC200MDL640 Input 24 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL241 Input 240 VAC (2 Groups of 8) 16
Points IC200MDL643 Input 5/12 VDC Pos/Neg Logic (2
Groups of 8) 16 Points
IC200MDL243 Input 120 VAC Isolated 16 Points IC200MDL644 Input 5/12 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
IC200MDL244 Input 240 VAC Isolated 8 Points IC200MDL650 Input 24 VDC Pos/Neg Logic (4
Groups of 8) 32 Points
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020