Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / other / Weidmüller 1806120000

Weidmüller 1806120000

Brand:Weidmüller 

Model number:1806120000

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.25kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Weidmüller 1806120000 Digital Input  Module






INQUIRE NOW

Products Name: Weidmüller 1806120000

PRODUCT DESCRIPTION

• Active power factor correction

• IEC EN61000-3-2 compliance

• Remote sense on main output

• Power fail and remote inhibit

• Single wire current sharing

• Built-in EMI filter

• Adjustable floating 4th output

• 2 Supervisory outputs 5 V and 12 V

• Overvoltage protection

• Overload protection

• Thermal overload protection

• DC power good

• Cover -C

• 120 KHz switching frequency

• Optional with fan cover -CF

• Optional end fan cover -CEF

Input range 85-264 VAC; 120-300 VDC 

Frequency 47-440 Hz

Inrush current 20 A max., cold start @ 25°C

Efficiency 75% typical at full load

EMI filter FCC Class B conducted and radiated

CISPR 22 Class B conducted and radiated

EN55022 Class B conducted and

radiated

VDE 0878 PT3 Class B conducted and

radiated.

Power factor 0.99 typical

Safety ground leakage 

current <0.5 mA @ 50/60 Hz, 264 VAC input

Output

Maximum power With cover: 250 W with 30 CFM forced

air, 

(-C) (-CF) (-CEF).

Adjustment range ±5% min. on main: 5-25 V on 4th output

Supervisory outputs 5 V @ 100 mA regulated, 12 V @ 500

mA

Hold-up time 16 ms @ 250 W load, 115 VAC nominal

line

Overload protection Short circuit protection on all outputs.

Case overload protected @ 110-145%

above peak rating

Overvoltage protection 5 V output: 5.7-6.7 VDC. 

Logic Control

Power failure TTL logic signal goes high 50-150 msec

after 5V output. It goes low at least 4

msec before loss of regulation

Remote on/off Requires an external contact (N.O or

N.C) to inhibit outputs

DC-OK TTL logic goes high 50-150 msec after 5

V output. It goes low when there is loss

of regulation.

Remote sense Compensates for 0.5 V lead drop min.

Will operate without remote sense

connected. Reverse connection

protected.

image.png

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Related products:

FACTORY171CCC96030EPSONSKP326-2
FAGORMCS-20LEquipeATM-407B-1-S-CE
FALCONSG2K-1TEquipeATM-4814
FALK97-0K0473-004EquipeATM-1918
FALKRK2040FZEquipeATM-1710
FALK2090GHB1-KBEquipePRE-300B-L-2-CCD
FERRAZA480R4R-1EricssonELU-D3
ferrocontrolBTR-12EricssonFSU925
FIDIACUR10ESTICENRZ-TU013-S
FieldServerFS-RA-CLX-BAS-406ESTICENRZ-AU30
FIFE CORP534738-001ESTICENRZ-AU40-20
FISHMANLDS9000-3ESTICENRZ-DU20
FLENDERKAF80KESTICENRZ-TU013-S
FLOWSERVE20-755W-120AESTICTNA1-CU20C
FLOWSERVE4MSX7ATESTICENRZ-TU013-OP
FlukePM6306ETELDSB2S154-211E-000H
FlukePM6681Eurotherm955D8R22
FMC3160-100-AEVIEWMT506LV4CN
FORCEPMC422FPEXCAVATORPC200LC-8
FORCECPU-30ZBEFACEPS3710A-T42-1G-NO60


E-mail: alex@fenoux.com

Tel.: +86 13338369201

Skype: +86  13338369201

WhatsApp: +86  13338369201