Brand: Schneider
Model number: 140CPU67160S
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.40kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
140CPU67160S SCHNEIDER
INQUIRE NOW
Products Name: 140CPU67160S SCHNEIDER
PRODUCT DESCRIPTION
Synchronous motors tolerate only extremely short interruptions of supply without loss of synchronism. In practice, the dead time should be sufficient to allow the motor no-volt device to operate. Typically, a minimum dead time of 0.2-0.3 seconds is recommended.
Description:
Remote Reset Module
The Remote Reset Module can be easily field installed on solid state overload relays. This module will
allow the overload relay to be reset from a remote location.
4 – 20 ma DC Communication Module
This module provides 4 - 20 madc output proportional to the percentage of current flowing to the motor,
according to the trip current adjustment setting. This feature works only on 9065 SF and ST overload relays.
Contact Units for Melting Alloy Type Overload Relays
One normally closed contact, Class 9998 Type SO1, is provided in each overload relay block on Type S
starters Sizes 00-4 and Size 6. On the Type S Size 5, a normally closed contact is provided with each of the
three overload relay blocks. The Class 9998 Type SO1 contact unit listed below is provided as standard in
each Class 9065 Type M melting alloy overload relay. Contact modules can be easily replaced and are
identified in the table below. Isolated overload relay alarm circuit contacts are available as an optional feature.
A pilot light or alarm bell can be wired in series with this contact to indicate that the overload relay has tripped.
For further information on isolated alarm contacts refer to Class 9999 Types SO4 and SO5.
Melting Alloy Overload Relay Jumper Strap Kits
Jumper strap kits are for use on three-phase manual or magnetic starters with melting alloy overload
relays only, where a three-phase starter is used to control a single-phase motor. These kits will include
two jumper straps, a wiring diagram showing how to wire a three-phase starter to control a single-phase
motor, and single-phase (one thermal unit) selection tables.
For Use With
Description Class 9999
Parts Kit Type NEMA Size
8536 SA-SJ 00B through 7 Remote Reset Module RR04k 9065 SS, SR, SF, ST 00B through 7
8536 SE-SF 3 and 4 Top Mounting Bracket RB34qk 9065 SS, SR, SF, ST 3 and 4
q To be used to mount the remote reset module on the top of the overload relay.
k 120Vac power required.
For Use With
Voltage Description Class 9999
Parts Kit Type NEMA Size
9065 SF, ST 00B through 7 120Vac 4-20 madc Output AO01
9065 SF, ST 0 through 4 24Vdc 4-20 madc Output AO02
Magnetic Starter Descriptionq Parts Kit
Number NEMA Size Type Series
00-4
& 6
SA-SF
SH A & B Standard N.C. contact unit Class 9998
Type SO1u
5 SG A Standard N.C. contact unit 31102-514-50
N.C. and N.O. alarm (three point) contact unit 31102-514-51
q Refer to Page 11-131 for contact ratings.
u The Type SO1 is also the replacement contact unit for Class 9065 Type M melting alloy overload relays.
Class
For Starter Class 9998 Kit
Type No. Size Type
ALL
00, 0, 1, 2
and M0 & M1
SA, SB, SC, SD and
M & T (Manual) SO31
3,4 SE, SF SO32
5 SG None Available
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020