The TAC Stainless Plate temperature sensors aremounted on the back of a 1 Gang stainless steelplate. The foam pad will insulate the sensor from any drafts in the wall. (2) 6/32” x 1” machine screws are provided for junction box mounting. Be sure that the sensor is not mounted on an outside wall, due to the extreme temperature changes from either drafts or heat transfer.
Description:
When the value given by the formula is greater than 3KV peak, it is necessary to use
Metrosils. They are connected across the relay circuit and they allow to shunt the secondary
current output of the current transformer from the relay in order to prevent very high
secondary voltages.
Metrosils are externally mounted and have annular discs shape.
Their operating characteristics is according to the formula:
V = C.I0.25
Where
− V: Instantaneous voltage applied to the non-linear resistor (Metrosil)
− C: Constant of the non-linear resistor (Metrosil)
− I: Instantaneous current through the non-linear resistor (Metrosil)
With the sinusoidal voltage applied across the Metrosil, the RMS current would be
approximately 0.25 times the peak current. This current value can be calculated as follows:
4
52.0 2).(
⎭
⎬
⎫
⎩
⎨
⎧ = C
Irms rmsVs
Where
− Vs(rms): RMS value of the sinusoidal voltage applied across the Metrosil.
This is due to the fact that the current waveform through the Metrosil is not sinusoidal but
appreciably distorted.
For satisfactory application of the non-linear resistor (Metrosil), its characteristics should
comply with the following requirements:
− At the relay voltage setting, the non-linear resistor (Metrosil) current should be as
low as possible, but no greater than approximately 30mA rms for 1A current
transformers and approximately 100mA rms for 5A current transformer.
− At the maximum secondary current, the non-linear resistor (Metrosil) should limit
the voltage to 1500V rms or 2120V peak for 0.25 second. At higher relay voltage
settings, it is not always possible to limit the fault voltage to 1500V rms, so higher
fault voltage may have to be tolerated.
The following tables show the typical types of Metrosil that will be required, depending on
relay current rating, REF voltage setting etc.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020