Brand: Schneider
Model number:171CCC96030
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.40kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
171CCC96030 SCHNEIDER
INQUIRE NOW
Products Name: 171CCC96030 SCHNEIDER
PRODUCT DESCRIPTION
Do NOT use the minimum-fuel contact as a part of any emergency stop sequence. The emergency may be caused by a governor malfunction which would also cause a malfunction of the minimumfuel feature. Use of the minimum-fuel contact for an emergency stop sequence could cause overspeed of the prime mover and mechanical
damage and personal injury, including death.
Description:
Replacing an MWTU11/TWL1111 Reverse Power / Forward Power Relay.
The MWTU11/TWL1111 was not strictly a power measuring relay. The relay operated using
an Icosø characteristic. Provided enough voltage was present to polarise the measuring
element, a 1% setting on a 1A relay would pickup at 10mA independent of the voltage
magnitude applied.
By selecting the 0.01 to 8Ien, model number MiCOM P125B, A setting range of 1 to 100% of
the nominal current in 0.1% steps is available.
2.6.5 Application of the Power Function
The standard configuration of the MiCOM P125 when set to use the wattmetric earth fault
protection can measure the zero sequence power, the connection for this can be found in the
sales publication and service manual. By adopting the connection above the relay can
measure the phase current and phase to phase, or phase to ground voltage, the operate
quantity when using these connections is a single phase power. As power protection is
generally required to operate for balanced three phase conditions basing the protection on a
single phase measured quantity is of no consequence.
When using the Power Function of the relay (Pe) care must be taken when selecting the
relay range. If the MiCOM P125CA relay is considered and is connected phase to ground
with 1A CT secondaries. A 0.2W setting would be equivalent to 0.2/63.5 Watts, 0.3% of the
nominal load.
2.7 Thermal Overload Protection (P126 & P127)
Thermal overload protection can be applied to prevent damages to the electrical plant
equipment when operating at temperatures in excess of the designed maximum withstand. A
prolonged overloading causes excessive heating, which may result in premature
deterioration of the insulation, or in extreme cases, insulation failure.
MiCOM P126 & P127 relays incorporate a current based thermal replica, using load current
to reproduce the heating and cooling of the equipment to be protected. The element thermal
overload protection can be set with both alarm and trip stages.
The heating within any plant equipment, such as cables or transformers, is of resistive type
(I²R x t). Thus, the quantity of heat generated is directly proportional to current squared (I²).
The thermal time characteristic used in the relay is based on current squared, integrated
over time.
The MiCOM P126 & P127 relays automatically use the highest phase current as input
information for the thermal model.
Protection equipment is designed to operate continuously at a temperature corresponding to
its full load rating, where heat generated is balanced with heat dissipated by radiation etc.
Over-temperature conditions therefore occur when currents in excess of rating are allowed to
flow for a certain period of time. It can be shown that temperatures during heating follow
exponential time constants and a similar exponential decrease of temperature occurs during
cooling.
In order to apply this protection element, the thermal time constant (Te) of the plant
equipment to be protected is therefore required.
The following sections will show that different plant equipment possesses different thermal
characteristics, due to the nature of their construction.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020