PRODUCT DESCRIPTION
Most of circuit breakers provide one trip-close-trip cycle. A delay time is necessary to return to the nominal state of the CB (for example, the spring that allows the circuit breaker to close should be fully charged). The state of the CB can be checked using an input assigned to the “CB FLT” function. If on completion of the “Ext CB Fail time” (tCFE), the “CB FLT” indicates a failed state of the CB, a lockout occur and the CB remains open.
Description:
Hand Reset Melting Alloy
Application
Hand reset melting alloy overload relays use a
eutectic alloy solder which responds to the heat
produced in a heater element by the motor
current. When tripped, the overload relay may be
reset manually after allowing a few minutes for the
motor and relay to cool and the solder to solidify.
Square D’s one-piece thermal unit construction
will provide overload protection for the majority of
motors. Repeated tripping does not affect the
original calibration. Melting alloy thermal units are
available in three designs: standard trip, slow trip
and quick trip.
Standard Trip (Class 20)–All standard trip thermal
units provide trip characteristics for normal motor
acceleration up to approximately 7 seconds on a
full voltage start.
Slow Trip (Class 30) – Type SB thermal units
provide trip characteristics for motor acceleration
up to approximately 12 seconds on a full voltage
start. The motor should be suitable for extended
starting periods.
Quick Trip (Class 10) – Type FB thermal units are
used to protect hermetically sealed, submersible
pump and other motors which can endure locked
rotor current for a very short time, or motors which
have a low ratio of locked rotor to full load current.
Replaceable Contacts – The contact modules of
Type S, F and G overload relays are replaceable.
Refer to Page 13.
Alarm Contacts – Contact modules with one N.O.
and one N.C. contact are available for Type S, F,
an G overload relays. For Type S, specify Form
Y34-2; for Types F and G, specify Form Y34.
Y34-2 indicates a four terminal isolated contact
module and Y34 indicates a three terminal module
with a common terminal between the N.O. and
N.C. contacts. Refer to Page 13.
Contact Ratings – For the overload relay control
circuit contact ratings refer to Page 13.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
SCHNEIDER 2704 SCHNEIDER 140CRA93200 SCHNEIDER 170ADM35010 SCHNEIDER BMEH584040C SCHNEIDER HMIGTO4310 SCHNEIDER TM221C24T SCHNEIDER TSXCUSBMBP SCHNEIDER 170ENT11002 SCHNEIDER 140CPU67160S SCHNEIDER 170NEF11021 SCHNEIDER 140cps11420 SCHNEIDER 140aci04000 SCHNEIDER 140aco02000 SCHNEIDER 140NOE77101 SCHNEIDER DAP212 SCHNEIDER LMC101CAA10000