Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / Schneider / AS-B875-100 SCHNEIDER

AS-B875-100 SCHNEIDER

Brand: Schneider

Model number:   AS-B875-100 

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.40kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

AS-B875-100   SCHNEIDER   Output module

INQUIRE NOW

Products Name: AS-B875-100 SCHNEIDER

PRODUCT DESCRIPTION

Most of circuit breakers provide one trip-close-trip cycle. A delay time is necessary to return to the nominal state of the CB (for example, the spring that allows the circuit breaker to close should be fully charged). The state of the CB can be checked using an input assigned to the “CB FLT” function. If on completion of the “Ext CB Fail time” (tCFE), the “CB FLT” indicates a failed state of the CB, a lockout occur and the CB remains open.

Description:

General

Overload relays are intended to protect motors, 

controllers, and branch-circuit conductors against 

excessive heating due to prolonged motor 

overcurrents up to and including locked rotor 

currents. Protection of the motor and the other 

branch-circuit components from higher currents, 

due to short circuits or grounds, is a function of the 

branch-circuit fuses, circuit breakers, or motor 

short-circuit protectors.

Nameplate Versus NEC Full-load Current

The 1996 NEC in Tables 430-147, 430-148, 430-

149 and 430-150 lists full-load currents according 

to motor horsepower and voltage. According to 

Article 430-6, these full-load currents should be 

used, rather than the motor nameplate full-load 

current, to determine the ampacity of conductors, 

ampere ratings of switches, or branch-circuit 

overcurrent devices, etc. It is specifically stated in 

Article 430-6, however, that “separate motorrunning overcurrent (overload) protection shall be 

based on the motor nameplate current rating.”

Service Factor

NEMA standards for motors list service factors of 

1.15 to 1.25 for general-purpose ac motors from 

1/2 to 200 horsepower. Other motors, such as 

totally-enclosed, fan-cooled, and motors over 200 

horsepower have a standard 1.0 service factor. 

Because of the way in which the standards are 

established, there is no simple way of determining 

the service factor without looking at the motor 

nameplate. For this reason all of the thermal unit 

selection tables in this catalog are designed for 

1.15 to 1.25 service factor motors, except the 

tables for Class 8198 High Voltage Starters. 

These tables are designed for 1.0 service factor. It 

is important to know when a motor has a service 

factor of 1.0, because failure to recognize this fact 

will result in an over-sized thermal unit selection 

and reduced motor protection.


BMEH584040C   SCHNEIDER

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

image.png

Related products:

SCHNEIDER  2704      SCHNEIDER  140CRA93200     SCHNEIDER  170ADM35010      SCHNEIDER  BMEH584040C     SCHNEIDER  HMIGTO4310    SCHNEIDER  TM221C24T      SCHNEIDER   TSXCUSBMBP    SCHNEIDER  170ENT11002     SCHNEIDER  140CPU67160S   SCHNEIDER 170NEF11021    SCHNEIDER  140cps11420     SCHNEIDER  140aci04000    SCHNEIDER  140aco02000     SCHNEIDER  140NOE77101      SCHNEIDER  DAP212     SCHNEIDER  LMC101CAA10000

E-mail:

alex@fenoux.com

Tel.:

+86 13376984225

Skype:

+86  13376984225

WhatsApp:

+86  13376984225