Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / Schneider / AS-BDEA-203 SCHNEIDER

AS-BDEA-203 SCHNEIDER

Brand: Schneider

Model number:   AS-BDEA-203 

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.40kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

AS-BDEA-203   SCHNEIDER

INQUIRE NOW

Products Name: AS-BDEA-203 SCHNEIDER

PRODUCT DESCRIPTION

The change of setting groups is only possible if there are no protection or automation functions running (except the thermal overload function). During the autorecloser cycle, if the relay receives an order to change setting groups, this order is kept in memory, and will only be executed after the timer has elapsed.

Description:

 • List the RADIUS servers (a maximum of two) available to the Rack ATS and the Reply Timeout 
period for each.
• Select a server, and configure the parameters for authentication by a new RADIUS server.
• Select a listed RADIUS server to display and modify its parameters.
Configure the RADIUS server
Summary of the configuration procedure
You must configure your RADIUS server to work with the Rack ATS.
For examples of the RADIUS users file with Vendor Specific Attributes (VSAs) and an example of an entry in 
the dictionary file on the RADIUS server, see the Security Handbook.
1. Add the IP address of the Rack ATS to the RADIUS server client list (file).
2. Users must be configured with Service-Type attributes unless Vendor Specific Attributes (VSAs) 
are defined. If no Service-Type attributes are configured, users will have read-only access (on the 
Web interface only).
3. See your RADIUS server documentation for information about the RADIUS users file, and see 
the Security Handbook for an example.
4. VSAs can be used instead of the Service-Type attributes provided by the RADIUS server. VSAs 
require a dictionary entry and a RADIUS users file. In the dictionary file, define names for 
ATTRIBUTE and VALUE keywords, but not for numeric values. If you change numeric values, 
RADIUS authentication and authorization will fail. VSAs take precedence over standard RADIUS 
attributes.
Configuring a RADIUS server on UNIX with shadow passwords
If UNIX shadow password files are used (/etc/passwd) with the RADIUS dictionary files, the following two 
methods can be used to authenticate users:
• If all UNIX users have administrative privileges, add the following to the RADIUS “user” file. To 
allow only Device Users, change the APC-Service-Type to Device.
DEFAULTAuth-Type = System
APC-Service-Type = Admin
• Add user names and attributes to the RADIUS “user” file, and verify the password against /etc/
passwd. The following example is for users bconners and thawk:
bconnersAuth-Type = System
APC-Service-Type = Admin
thawkAuth-Type = System
APC-Service-Type = Device 


AS-BDEP-112   SCHNEIDER

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

image.png

Related products:

2704

140CRA93200

170ADM35010

170LNT71000

BMEH584040C

HMIGTO4310 

TM221C24T

TSXCUSBMBP

170ENT11002

140CPU67160S

170NEF11021

140cps11420

140aci04000

140aco02000

140NOE77101

DAP212

LMC101CAA10000