AS-E381-902 SCHNEIDER
INQUIRE NOW
Products Name: AS-E381-902 SCHNEIDER
PRODUCT DESCRIPTION
The change of setting groups is only possible if there are no protection or automation functions running (except the thermal overload function). During the autorecloser cycle, if the relay receives an order to change setting groups, this order is kept in memory, and will only be executed after the timer has elapsed.
Description:
Setpoint Dial Range: Dual marked 35 to 60°F (1.7 to 15.5°C).
Sensing Element: Vapor pressure type, copper construction.
Response: To lowest temperature sensed by any one-foot section of its element. Altitude
causes the control to operate approximately 1°F colder per 1000 ft. of elevation.
Differential: 5°F (3°C) fixed.
Electrical Switch: Snap action SPDT or DPST. Refer to Table-1.
Ratings, Refer to Table-1 and Table-2.
Connections:
TC-52xx, Screw terminals.
Mounting: In any position on any surface not subject to excessive vibration.
Housing: Molded gray PVC plastic cover with a zinc-plated steel main enclosure with a 1/2
in. conduit opening.
Ambient Temperature Limits:
Shipping and Storage, -40 to 150°F (-40 to 66°C).
Operating, Must be 5°F (3°C) above setpoint to a maximum of 150°F (66°C) at case.
Thermal Sensing Element, 300°F (149°C).
Humidity:
Enclosure, 5 to 95% RH, non-condensing.
Thermal Sensing Element, 0 to 100% RH.
Enclosure Rating: NEMA Type 1.
Dimensions:
Case, 2.7 H x 3.44 W x 1.97 D in. (69 x 87 x 50 mm).
Element, 3/32 in. O.D. x 20 ft. length (2.4 mm x 6.1 m).
Agency Approvals: UL 873 Temperature-Indicating and -Regulating Equipment and CSA
Certified.
Table-1 Model Chart.
Table-2 DC Ratings for TC-5232 Only.
Model
Number Device Type Electrical
Switch
Voltage
Vac
Full
Load
Amps
Locked
Rotor
Amps
Pilot
Duty
(VA)
Non-Inductive
Amps
TC-5231 Low temp
auto reset SPDTe
24a — — 100 16
120
17 102 720 24 208
240c
277 — — — 7.2
TC-5232 Low temp
auto reset DPSTd
24a — — 100 16
120c
24 144 125 24 208c
240c
277 — — — 7.2
TC-5241 Low temp
manual resetb SPDTe
24a — — 100 16
120
17 102 720 24 208
240c
277 — — — 7.2
a Less than 0.5 Amp is not recommended.
b Reset cannot be accomplished until the sensed temperature is at least 5°F above setpoint.
c Full load and locked rotor ratings are suitable for hermetic compressors only.
d Limit two separate circuit loads with common return to < 5885 VA. Only one load may be a motor load. e Do not exceed pilot duty rating on one side of switch.
Volts FLA LRA NIA PD VA
120 4.6 46 3 57.5
240 2.3 23 0.5 57.5
600 — — — 57.5
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000