Brand: Schneider
Model number: AS-E685-904
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.40kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
AS-E685-904 SCHNEIDER
INQUIRE NOW
Products Name: AS-E685-904 SCHNEIDER
PRODUCT DESCRIPTION
The autoreclose function provides the ability to automatically control the autorecloser (two, three or four shot cycle, settable using “Phase Cycles” and “E/Gnd Cycles” menu). Dead times for all the shots (reclose attempts) can be independently adjusted.
Description:
Setpoint Dial Range: Dual marked 35 to 60°F (1.7 to 15.5°C).
Sensing Element: Vapor pressure type, copper construction.
Response: To lowest temperature sensed by any one-foot section of its element. Altitude
causes the control to operate approximately 1°F colder per 1000 ft. of elevation.
Differential: 5°F (3°C) fixed.
Electrical Switch: Snap action SPDT or DPST. Refer to Table-1.
Ratings, Refer to Table-1 and Table-2.
Connections:
TC-52xx, Screw terminals.
Mounting: In any position on any surface not subject to excessive vibration.
Housing: Molded gray PVC plastic cover with a zinc-plated steel main enclosure with a 1/2
in. conduit opening.
Ambient Temperature Limits:
Shipping and Storage, -40 to 150°F (-40 to 66°C).
Operating, Must be 5°F (3°C) above setpoint to a maximum of 150°F (66°C) at case.
Thermal Sensing Element, 300°F (149°C).
Humidity:
Enclosure, 5 to 95% RH, non-condensing.
Thermal Sensing Element, 0 to 100% RH.
Enclosure Rating: NEMA Type 1.
Dimensions:
Case, 2.7 H x 3.44 W x 1.97 D in. (69 x 87 x 50 mm).
Element, 3/32 in. O.D. x 20 ft. length (2.4 mm x 6.1 m).
Agency Approvals: UL 873 Temperature-Indicating and -Regulating Equipment and CSA
Certified.
Table-1 Model Chart.
Table-2 DC Ratings for TC-5232 Only.
Model
Number Device Type Electrical
Switch
Voltage
Vac
Full
Load
Amps
Locked
Rotor
Amps
Pilot
Duty
(VA)
Non-Inductive
Amps
TC-5231 Low temp
auto reset SPDTe
24a — — 100 16
120
17 102 720 24 208
240c
277 — — — 7.2
TC-5232 Low temp
auto reset DPSTd
24a — — 100 16
120c
24 144 125 24 208c
240c
277 — — — 7.2
TC-5241 Low temp
manual resetb SPDTe
24a — — 100 16
120
17 102 720 24 208
240c
277 — — — 7.2
a Less than 0.5 Amp is not recommended.
b Reset cannot be accomplished until the sensed temperature is at least 5°F above setpoint.
c Full load and locked rotor ratings are suitable for hermetic compressors only.
d Limit two separate circuit loads with common return to < 5885 VA. Only one load may be a motor load. e Do not exceed pilot duty rating on one side of switch.
Volts FLA LRA NIA PD VA
120 4.6 46 3 57.5
240 2.3 23 0.5 57.5
600 — — — 57.5
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020