Brand: Schneider
Model number: AS-WBXT-201
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.40kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
AS-WBXT-201 SCHNEIDER
INQUIRE NOW
Products Name: AS-WBXT-201 SCHNEIDER
PRODUCT DESCRIPTION
This specific counter avoids a frequent operation of a CB in case of frequent intermittent fault. The numbers of shoot can be adjusted from 1 to 100 in the cell “Max cycles nb”, settable in a time period from 10min to 24 hours.
Description:
Read carefully the safety information in the user manual and the catalog. Before starting up the drive, please check the following points
regarding mechanical and electrical installations, then use and run the drive.
For complete documentation, refer to www.schneider-electric.com.
1. Mechanical installation
• Refer to the Mounting and temperature conditions instructions on page 13 for drive mounting types and recommendations on the
ambient temperature.
• Mount the drive vertically as specified, see Mounting and temperature conditions instructions on page 13.
• The use of the drive must be in agreement with the environments defined by the standard 60721-3-3 and according to the levels
defined in the catalog.
• Mount the options required for your application, refer to the catalog.
2. Electrical installation
• Connect the drive to the ground, see Equipment grounding on page 16.
• Ensure that the input power voltage corresponds to the drive nominal voltage and connect the line supply as shown in General wiring
diagram on page 18.
• Ensure you use appropriate input power fuses and circuit breaker, see in the Annex (S1A58684) delivered with the drive.
• Wire the control terminals as required, see Control terminals on page 23. Separate the power cable and the control cable according
to the EMC compatibility rules on page 26.
• The ATV12ppppM2 range integrates an EMC filter. The leakage current can be reduced using the IT jumper as explained in the
paragraph Internal EMC filter on ATV12ppppM2 on page 28.
• Ensure that motor connections correspond to the voltage (star, delta).
3. Use and run the drive
• Start the drive and you will see Standard motor frequency bFr page 45 at the first power-on. Check that the frequency defined by
the frequency bFr (the factory setting is 50 Hz) is in accordance with the frequency of the motor, see First power-up on page 34.
For the following power-on, you will see rdY on the HMI.
• MyMenu (upper part of CONF mode) allows you to configure the drive for most applications (see page 45).
• Factory / recall customer parameter set FCS function page 46 allows you to reset the drive with factory settings.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020