Brand: Schneider
Model number:XBTFC044310
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.40kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
XBTFC044310 SCHNEIDER
INQUIRE NOW
Products Name: XBTFC044310 SCHNEIDER
PRODUCT DESCRIPTION
As soon as a phase threshold is running, the instantaneous output associated with this threshold is activated. This output indicates that the protection element has detected a phase fault and that the time delay associated with the threshold has started.
Description:
Application Considerations
The protection Pe> and Pe>> require relay current and voltage connections to be actived.
The measurement of the Pe depends on the voltage wiring of the relay.
In case of 3Vpn wiring the Ve will be equal to Ve= 1/3(Va+VB+VC) in the other insertions
way the applied voltage to the relay is directly used to calculate the Pe.
Referring to the relevant application diagram for the P125, P126 and P127 relays, it should
be installed such that its direction for forward operation is 'looking into' the protected feeder
i.e. away from the busbar, with the appropriate RCA .
Resistance earthed systems 180°
Insulated systems 270°
Petersen Coil system 200°
Transmission Systems (solidly earthed) 90°-120°
As illustrated in the relay application diagram, it is usual for the earth fault element to be
driven from a core balance current transformer. This eliminates the possibility of spill current
that may arise from slight mismatches between residually connected line CTs. It also
enables a much lower CT ratio to be applied, thereby allowing the required protection
sensitivity to be more easily achieved.
2.4.5 Iecos protection
The Iecos protection follows the same concepts of the Pe protection.
The difference is that the thresholds take in account the active component of the earth fault
current.
The setting of the RCA follows the above listed table.
2.4.6 Where use Iecos and where use Pe.
The wattmetric protection Pe/Iecos is almost used in the Petersen Coil systems.
In a Petersen Coil scheme during a fault we have a resistive current and an inductive
current.
The resistive current is constant because the residual voltage is always present; the
inductive current is the summation of the capacitive contribution of the healthy line and the
reactive contribution of the fault line.
In this situation is difficult to discriminate the line and detect the fault current value because
the capacitive and reactive are of opposite sign.
Since the residual voltage is present to the parallel between the coil and resistance a
wattmetric protection is used to be sure to open the fault line.
The unique resistive present component depends on the fault line.
The discriminative for the using of Pe or Iecos protection is the fault current value and the
relative fault operating boundary.
In some applications, the residual current on the healthy feeder can lie just inside the
operating boundary following a fault condition. The residual current for the faulted feeder lies
close to the operating boundary
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
2704
140CRA93200
170ADM35010
170LNT71000
BMEH584040C
HMIGTO4310
TM221C24T
TSXCUSBMBP
170ENT11002
140CPU67160S
170NEF11021
140cps11420
140aci04000
140aco02000
140NOE77101
DAP212
LMC101CAA10000
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020