2301A 9907-018   WOODWARD

INQUIRE NOW

Products Name: 2301A 9907-018 WOODWARD

PRODUCT DESCRIPTION

If the panel meters show that the generator voltage is different from that of the bus, the voltage offset potentiometer may need adjustment. Make sure that the 

panel meters are accurate, calibrated, and at operating temperature. Most panel meters are accurate to ±3% and are not temperature compensated.

Benefits:

This section describes the general theory of operation of the two versions of the 

SPM-A Synchronizer. Figure 1-1 shows the SPM-A Synchronizer with voltage 

matching. Figure 1-2 shows a typical synchronizer system block diagram. Figure 

1-3 shows a functional block diagram of the synchronizer. 

Synchronizer Inputs 

The SPM-A Synchronizer checks the phase angle and frequency of the bus and 

an off-line generator which is to be paralleled. The voltage inputs from the bus 

and generator are first applied to separate signal conditioner circuits. Each signal 

conditioner is a filter which changes the shape of the voltage input signals so 

they can be accurately measured. A phase offset potentiometer in the signal 

conditioner circuit is adjusted to compensate for phase errors. (This adjustment is 

factory set with identical bus and generator inputs. It should be readjusted only 

where a phase offset has been caused through the line transformers of the 

installation.) The signal conditioners also amplify the bus and generator signals 

and apply them to the phase detector. 

Operating Modes 

A user-installed mode switch (single-pole, four-position) controls the relay driver. 

The switch must be wired to synchronizer contacts 10 through 13 (see the plant 

wiring drawing). The four positions are OFF, RUN, CHECK, and PERMISSIVE. 

When the switch is OFF, the synchronizer is out of operation. 

The RUN mode allows normal synchronizer operation and breaker closure 

signals. The speed bias circuit continues to operate to maintain synchronization 

for one second to allow time for the breaker closure signal. When one second 

has elapsed, the lockout circuit activates to disable the synchronizer. The lockout 

circuit is reset automatically when the relative phase angle exceeds the window 

limit after the generator is disconnected from the bus. 

The CHECK mode allows normal synchronizing and voltage matching, but does 

not permit a breaker closure signal.

2301A 9907-018   WOODWARD

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

image.png

Related products:

9907-018

DSS-2

5464-643

5466-031

5466-253

5466-258

5466-348

5466-353

5501-367

5501-376

5464-658

5466-409

9907-838

9907-014

9905-131

9907-186

9907-414

9907-838

9970-164

5441-413

9905-003

505-4532

8200-224

1247-007

1326-183

1355-169

5210-543

5464-551

8250-565

8290-195

8405-307

8406-113