Products Name: 5437-282 WOODWARD
PRODUCT DESCRIPTION
Before handling the control, read page ii, "Electrostatic Discharge Awareness". Be careful when unpacking the electronic control. Check the control for signs of
damage such as bent or dented panels, scratches, and loose or broken parts. Notify the shipper of any damage.
Benefits:
This section describes the general theory of operation of the two versions of the
SPM-A Synchronizer. Figure 1-1 shows the SPM-A Synchronizer with voltage
matching. Figure 1-2 shows a typical synchronizer system block diagram. Figure
1-3 shows a functional block diagram of the synchronizer.
Synchronizer Inputs
The SPM-A Synchronizer checks the phase angle and frequency of the bus and
an off-line generator which is to be paralleled. The voltage inputs from the bus
and generator are first applied to separate signal conditioner circuits. Each signal
conditioner is a filter which changes the shape of the voltage input signals so
they can be accurately measured. A phase offset potentiometer in the signal
conditioner circuit is adjusted to compensate for phase errors. (This adjustment is
factory set with identical bus and generator inputs. It should be readjusted only
where a phase offset has been caused through the line transformers of the
installation.) The signal conditioners also amplify the bus and generator signals
and apply them to the phase detector.
Operating Modes
A user-installed mode switch (single-pole, four-position) controls the relay driver.
The switch must be wired to synchronizer contacts 10 through 13 (see the plant
wiring drawing). The four positions are OFF, RUN, CHECK, and PERMISSIVE.
When the switch is OFF, the synchronizer is out of operation.
The RUN mode allows normal synchronizer operation and breaker closure
signals. The speed bias circuit continues to operate to maintain synchronization
for one second to allow time for the breaker closure signal. When one second
has elapsed, the lockout circuit activates to disable the synchronizer. The lockout
circuit is reset automatically when the relative phase angle exceeds the window
limit after the generator is disconnected from the bus.
The CHECK mode allows normal synchronizing and voltage matching, but does
not permit a breaker closure signal.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
9907-018
DSS-2
5464-643
5466-031
5466-253
5466-258
5466-348
5466-353
5501-367
5501-376
5464-658
5466-409
9907-838
9907-014
9905-131
9907-186
9907-414
9907-838
9970-164
5441-413
9905-003
505-4532
8200-224
1247-007
1326-183
1355-169
5210-543
5464-551
8250-565
8290-195
8405-307
8406-113
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020