Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / WoodWard / 5463-033 WOODWARD

5463-033 WOODWARD

Brand:  WoodWard

Model number:5463-033 

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.85kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

5463-033   WOODWARD

INQUIRE NOW

Products Name: 5463-033 WOODWARD

PRODUCT DESCRIPTION

One side of the secondary of all CTs must be earthed. The earth connection should be made on the side of the secondary facing the protected object. The polarity of the CTs must be in accordance with the following diagram.

Benefits:

Even though governor faults cause improper prime mover operation, improper 

prime mover operation can be also caused by other items such as low fuel 

pressure. When the prime mover stops working properly, find out which part is 

defective. Do this by: 

1. Substituting, if available, a part that works for the one suspected of causing 

the problem. 

2. Simplifying the system. Remove options and observe performance after 

each removal. 

3. Testing the parts suspected of causing the problem. Follow the 

manufacturer’s instructions or set up input and operating conditions which 

produce known outputs. 

To test the EPG, use Chapter 2 to verify that the installation is correct and 

perform the installation check. Those checks are the best way to test the EPG. 

The Preset Rated Speed section (under Step 6 of the Installation Checks in 

Chapter 2) is the best test of the EPG’s ability to control speed. It requires the 

use of a signal generator with an isolated output. If appropriate, do the checks for 

Paralleled Generator Applications with the Load Sensor (referenced in Chapter 2, 

manual 82313). 

Other Checks 

Do the installation checks described in the previous paragraph first. Then check 

the following: 

1. If the prime mover is stable at some speeds or power outputs but oscillates 

at others, the linkage may not be compatible with the fuel control. Refer to 

Linkage Compatibility under Actuator Mounting and Linkage in Chapter 2. 

2. If the prime mover oscillates at low frequency (about 1 Hz) and the Gain and 

Stability adjustments (in Chapter 2) are correct, then friction in the linkage 

may be the cause. 

· Disconnect the actuator from the fuel control. 

· Manually stroke the fuel control linkage from stop to stop as if the 

actuator were moving it. The linkage must move freely without friction 

and without backlash. Lubricate or replace linkage or fuel control parts 

as required. 

3. If the prime mover is unstable only when load sharing, verify that: 

· Load sensor CTs and PTs are wired correctly. 

· Voltage regulator droop or cross current compensation is set correctly. 

· The voltage regulator is not intermittent or otherwise faulty. 

 If the problem is still there, reduce the load gain a little and set the load gain 

pot on all other load sensors in the system for the same load signal at full 

load. It may be necessary to reduce the load signal to 3 volts in extreme 

cases. Consult with your authorized Distributor or with Woodward in such 

cases.


5463-033   WOODWARD

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

image.png

Related products:

9907-018

DSS-2

5464-643

5466-031

5466-253

5466-258

5466-348

5466-353

5501-367

5501-376

5464-658

5466-409

9907-838

9907-014

9905-131

9907-186

9907-414

9907-838

9970-164

5441-413

9905-003

505-4532

8200-224

1247-007

1326-183

1355-169

5210-543

5464-551

8250-565

8290-195

8405-307

8406-113