Brand: WoodWard
Model number:5463-482
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.85kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
5463-482 WOODWARD
INQUIRE NOW
Products Name: 5463-482 WOODWARD
PRODUCT DESCRIPTION
Before handling the control, read page ii, "Electrostatic Discharge Awareness". Be careful when unpacking the electronic control. Check the control for signs of
damage such as bent or dented panels, scratches, and loose or broken parts. Notify the shipper of any damage.
Benefits:
Speed Control
The basic speed control components and connections are shown in Figure 1-1.
There are no mechanical drive or hydraulic connections. All input power comes
from the battery. The speed control compares the actual speed with the desired
speed. It then calculates an error signal and drives the actuator in the increase or
decrease fuel direction to correct prime mover speed.
Figure 4-1 shows the Electrically Powered Governor in more detail. The speed
control is housed in a die-cast aluminum enclosure.
The EPG has two control loops. The speed loop ensures prime mover speed
remains constant. The current loop ensures proper drive to the actuator.
Speed Loop
The speed loop controller has two inputs: the desired speed (speed reference
signal) and the actual speed (the speed sensor signal). It compares the two and
calculates an error signal which includes dynamic response considerations. Gain
and stability adjustments tailor the governor’s response to the requirements of
the specific prime mover. Rated speed is set by the rated speed pot and, if
attached, a speed trim pot. The idle reference is controlled by an external idle
speed pot. Rated speed should be set before idle speed. Speed sensor output is
a voltage proportional to magnetic pickup frequency. The frequency range of the
magnetic pickup is set by an internal resistor. The specific frequency range of a
specific EPG Speed Control is indicated by the part number of the speed control.
Current Loop
The current loop error signal can be considered a command for the correct
amount of actuator current.
The actuator’s controller circuit compares actual current (from the current sensor
circuit) to the desired current level (from the speed loop controller) and generates
a current loop error signal. To make the current driver efficient, it is operated as a
switch. Actuator current is changed by changing the duty cycle. The pulse width
modulator converts the current loop error signal from a dc voltage to a switching
signal. For this reason measurements of speed control output [3 (+) and 4 (–)]
indicate only general conditions. Excessive currents are prevented from flowing
through the actuator coil by the energy limiter. It prevents the actuator from
overheating but allows enough current to keep the actuator at the maximum fuel
position.
The auxiliary input is jumpered except when a Load Sensor is added for
paralleled generator applications. There is a failsafe circuit which senses MPU
frequency and forces the pulse width modulator input to zero if the MPU
frequency or voltage are below acceptable limits, as they would be if an MPU
wire broke.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
9907-018
DSS-2
5464-643
5466-031
5466-253
5466-258
5466-348
5466-353
5501-367
5501-376
5464-658
5466-409
9907-838
9907-014
9905-131
9907-186
9907-414
9907-838
9970-164
5441-413
9905-003
505-4532
8200-224
1247-007
1326-183
1355-169
5210-543
5464-551
8250-565
8290-195
8405-307
8406-113
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020