Large stock, please search or inquiry

Fenoux Electric Co., Ltd.
Home / Products / WoodWard / 8552-558 WOODWARD

8552-558 WOODWARD

Brand:  WoodWard

Model number:8552-558 

Colour:new                  

Warranty: 12 months

Lead Time:3-day working day   

Country of origin: USA Price: Please contact us         

Product weight:0.85kg

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

8552-558   WOODWARD


INQUIRE NOW

Products Name: 8552-558 WOODWARD

PRODUCT DESCRIPTION

Woodward has launched hardware and software updates to address many CIP requirements; however, complete NERC/CIP compliance involves more than the controls and is dependent on plant infrastructure and procedures. The physical security remains the user’s responsibility.

Benefits:

The ESDR 4 is a three-phase current differential protection relay for generators and motors (protected object). 

The currents flowing in the individual lines are each measured using a current transformer on both sides of the 

protected object. They form the protection area boundary or zone. All two or three-phase short circuits and lineto-earth faults within this protection area are detected by the ESDR 4 as fault currents which initiate tripping.The 

unit does not trip if fault currents occur outside the protection zone. In this way, a selective protection is guaranteed. 

The unit monitors six (6) measured currents via isolated inputs. The unit calculates internally the restraint current 

(Is) and the differential current (Id) separately for each phase. The actual values of the calculated parameters (Differential current Id und Restraint current IS) are shown on the display either as absolute values or as a percentage 

of the generator rated current (selectable in locked input mode). 

Theoretically the currents Ia and Ib are equal, both in fault-free operation and outside the protection zone (Figure 

4-1-a).The difference is zero and the differential protection does not initiate. However, in practice current differentials do occur (= spurious currents), even in fault-free operation. They result, for example, from summation or 

phase angle errors in the CTs, which are influenced by deviating burden values. These spurious currents remain 

small inside the operating range, but increase with increasing load and are especially high when one or more CTs 

become saturated (e.g. in the case of an external short circuit). In order to prevent a tripping of the relay due to 

spurious currents, the trigger threshold is not held statically constant but increases in relation to the restraint current Is. Spurious currents need to be taken into account when adjusting the trip characteristic. 

When a fault occurs inside the protection area (Figure 4-1-b), unequal currents flow in the CTs, which result in a 

current differential. If this exceeds the differential protection threshold, the relay will trip.

8552-674   WOODWARD

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

image.png

Related products:

9907-018

DSS-2

5464-643

5466-031

5466-253

5466-258

5466-348

5466-353

5501-367

5501-376

5464-658

5466-409

9907-838

9907-014

9905-131

9907-186

9907-414

9907-838

9970-164

5441-413

9905-003

505-4532

8200-224

1247-007

1326-183

1355-169

5210-543

5464-551

8250-565

8290-195

8405-307

8406-113