8561-6540 WOODWARD
INQUIRE NOW
Products Name: 8561-6540 WOODWARD
PRODUCT DESCRIPTION
If the panel meters show that the generator voltage is different from that of the bus, the voltage offset potentiometer may need adjustment. Make sure that the
panel meters are accurate, calibrated, and at operating temperature. Most panel meters are accurate to ±3% and are not temperature compensated.
Benefits:
Power supply output must be low impedance (for example, directly from
batteries). DO NOT power low-voltage versions of the control from high-voltage
sources with resistors and zener diodes in series with the control power input.
The 2301A control contains a switching power supply which requires a current
surge to start properly.
To prevent damage to the control, do not power low-voltage versions
of the control from high-voltage sources.
High and low voltage models of 2301A Speed Controls are available. Low
voltage models require a supply of 10 to 40 Vdc, 12 W. High voltage models
require a supply of 88 to 120 Vac or 90 to 150 Vdc., 12 W. The ac supply may be
50 to 400 Hz.
If a battery is used for operating power, an alternator or other battery charging
device is necessary to maintain a stable supply voltage.
To prevent damage to the control, make sure that the alternator or
other battery-charging device is not connected to the control when
the battery is disconnected from the control.
Location Considerations
Consider these requirements when selecting the mounting location:
· Adequate ventilation for cooling
· Space for servicing and repair
· Protection from direct exposure to water or to a condensation-prone
environment
· Protection from high-voltage or high-current devices, or devices which
produce electromagnetic interference
· Protection from excessive vibration
· An ambient operating temperature range of –40 to +85 °C (–40 to +185 °F)
Do not mount the control on the engine.
Electrical Connections
External wiring connections and shielding requirements for a typical control
installation are shown in the plant wiring diagram, Figures 2-4 and 2-5. These
wiring connections and shielding requirements are explained in the balance of
this section.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
9907-018
DSS-2
5464-643
5466-031
5466-253
5466-258
5466-348
5466-353
5501-367
5501-376
5464-658
5466-409
9907-838
9907-014
9905-131
9907-186
9907-414
9907-838
9970-164
5441-413
9905-003
505-4532
8200-224
1247-007
1326-183
1355-169
5210-543
5464-551
8250-565
8290-195
8405-307
8406-113
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020