9905-895 WOODWARD
INQUIRE NOW
Products Name: 9905-895 WOODWARD
PRODUCT DESCRIPTION
Prior to commissioning ensure that all measuring devices are connected in correct phase sequence. The connect command for the unit circuit breaker must bedisconnected at the unit circuit breaker. The field rotation must be monitored for proper rotation. Any absence of or incorrect connection of voltage measuring devices or other signals may lead to malfunctions and damage the unit, the engine, and/or components connected to the unit
Benefits:
Shielded wires to be twisted pairs or twisted 3-conductor, grounded at one end only.
2. 4 or 2 mm² (12 or 14 AWG) stranded wire, must be as short as possible and routed
as a pair ≤10 mm apart. Total of distance from battery to control, and from control to
actuator, to be as short as possible (see maximum length in chart).
Note: In expensive AC to DC Battery chargers used for maintaining the battery
charge allow moderate surges from the AC mains to couple to DC power:
To protect the EPG a surge arrestor of at least the energy & voltage
capability of a V47ZA7 MOV should be placed from battery minus to battery
plus terminals.
3. See EPG Models above for source voltages.
4. Open for minimum fuel. Do not use either the minimum fuel option, or disconnect the
actuator leads, or disconnect the power to the control as part of any emergency stop
sequence.
5. For positive ground systems, switch and fuse to be located in series with battery (–)
and terminal 2. Positive (+) terminal becomes chassis ground. Leads from battery to
terminals 1 and 2 must be direct and not pass through distribution points.
6. Approximate speed change with trim potentiometer:
±2.5% using a 1 kΩ potentiometer
±5% using a 2 kΩ potentiometer
7. About one second ramp time per 50 µF. Capacitor specification: 200 µF maximum,
15 W minimum, less than 30 µAdc leakage current over temperature range.
8. Idle range about 25% to 200% of rated, using 50 k potentiometer. For fixed idle,
calculate the value of the resistor:
R = 17 kΩ ( Rated Speed
Idle Speed – 1 )
9. 512/24 and 1712/24 use a 10 A fuse.
10. Polarity not important.
11. With a balanced load and unity power factor (PF=1), the current transformer should
be wired in the correct potential leg, and must be phased at the control so the
potential at terminal 9 to 10 is in phase with the CT from terminal 11 to 12.
12. Power source current transformers should be sized to produce a 5 A secondary
current, with maximum generator current. CT burden is essentially 0 VA.
13. Absolute minimum signal must be 95 Vrms. Absolute maximum signal must be 260
Vrms. Potential transformer burden is 20 VA.
14. This control contains an internal current transformer. This transformer must be
connected across the power source transformer whenever the unit is running to
prevent lethal high voltage from developing on leads to these terminals.
15. On systems without a neutral, the voltage at terminal 9 to 10 is 1.73 times N2/N1
times the line-to-line voltage
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
9907-018
DSS-2
5464-643
5466-031
5466-253
5466-258
5466-348
5466-353
5501-367
5501-376
5464-658
5466-409
9907-838
9907-014
9905-131
9907-186
9907-414
9907-838
9970-164
5441-413
9905-003
505-4532
8200-224
1247-007
1326-183
1355-169
5210-543
5464-551
8250-565
8290-195
8405-307
8406-113
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020