PRODUCT DESCRIPTION

Prior to commissioning ensure that all measuring devices are connected in correct phase sequence. The connect command for the unit circuit breaker must bedisconnected at the unit circuit breaker. The field rotation must be monitored for proper rotation. Any absence of or incorrect connection of voltage measuring devices or other signals may lead to malfunctions and damage the unit, the engine, and/or components connected to the unit

Benefits:

Shielded wires to be twisted pairs or twisted 3-conductor, grounded at one end only. 

2. 4 or 2 mm² (12 or 14 AWG) stranded wire, must be as short as possible and routed 

as a pair ≤10 mm apart. Total of distance from battery to control, and from control to 

actuator, to be as short as possible (see maximum length in chart). 

Note: In expensive AC to DC Battery chargers used for maintaining the battery 

charge allow moderate surges from the AC mains to couple to DC power: 

To protect the EPG a surge arrestor of at least the energy & voltage 

capability of a V47ZA7 MOV should be placed from battery minus to battery 

plus terminals.

3. See EPG Models above for source voltages. 

4. Open for minimum fuel. Do not use either the minimum fuel option, or disconnect the 

actuator leads, or disconnect the power to the control as part of any emergency stop 

sequence. 

5. For positive ground systems, switch and fuse to be located in series with battery (–) 

and terminal 2. Positive (+) terminal becomes chassis ground. Leads from battery to 

terminals 1 and 2 must be direct and not pass through distribution points. 

6. Approximate speed change with trim potentiometer: 

 ±2.5% using a 1 kΩ potentiometer 

 ±5% using a 2 kΩ potentiometer 

7. About one second ramp time per 50 µF. Capacitor specification: 200 µF maximum, 

15 W minimum, less than 30 µAdc leakage current over temperature range. 

8. Idle range about 25% to 200% of rated, using 50 k potentiometer. For fixed idle, 

calculate the value of the resistor: 

R = 17 kΩ ( Rated Speed

Idle Speed – 1 )

9. 512/24 and 1712/24 use a 10 A fuse. 

10. Polarity not important. 

11. With a balanced load and unity power factor (PF=1), the current transformer should 

be wired in the correct potential leg, and must be phased at the control so the 

potential at terminal 9 to 10 is in phase with the CT from terminal 11 to 12. 

12. Power source current transformers should be sized to produce a 5 A secondary 

current, with maximum generator current. CT burden is essentially 0 VA. 

13. Absolute minimum signal must be 95 Vrms. Absolute maximum signal must be 260 

Vrms. Potential transformer burden is 20 VA. 

14. This control contains an internal current transformer. This transformer must be 

connected across the power source transformer whenever the unit is running to 

prevent lethal high voltage from developing on leads to these terminals. 

15. On systems without a neutral, the voltage at terminal 9 to 10 is 1.73 times N2/N1 

times the line-to-line voltage

9905-796   WOODWARD

Shipping Port:  China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

image.png

Related products:

9907-018

DSS-2

5464-643

5466-031

5466-253

5466-258

5466-348

5466-353

5501-367

5501-376

5464-658

5466-409

9907-838

9907-014

9905-131

9907-186

9907-414

9907-838

9970-164

5441-413

9905-003

505-4532

8200-224

1247-007

1326-183

1355-169

5210-543

5464-551

8250-565

8290-195

8405-307

8406-113