Brand: WoodWard
Model number:EGCP-2 8406-121
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Country of origin: USA Price: Please contact us
Product weight:0.85kg
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
EGCP-2 8406-121 WOODWARD
INQUIRE NOW
Products Name: EGCP-2 8406-121 WOODWARD
PRODUCT DESCRIPTION
To prevent damage to electronic components caused by improper handling, read and observe the precautions in Woodward manual 82715, Guide for Handling and Protection of Electronic Controls, Printed Circuit Boards, and Modules.
Benefits:
The speed-signal voltage is compared to the reference voltage at the summing
point. If the speed-signal voltage is lower or higher than the reference voltage, a
signal is sent by the control amplifier calling for an increase or decrease in
speed. The actuator is controlled by this signal, repositioning the fuel valve or
rack until the speed-signal voltage and the reference voltage are equal.
Auxiliary Inputs
Terminals 11 through 17 are used for auxiliary inputs which change the reference
voltage and thus the output of the speed control. These inputs include speed
trim, droop, SPM synchronizer, and the auxiliary input, (usually from a load
sensor and parallel lines).
Failed Speed Signal Circuit
A failed-speed-signal circuit monitors the speed-signal input. When no signal is
detected, it calls for minimum fuel. The minimum-fuel signal is sufficient to cause
the actuator to go to the minimum position. Incorrect linkage adjustments or other
restrictions in the external system may prevent prime-mover shutdown.
For controls with actuator current of 20 to 160 mA, minimum fuel is defined as:
· Actuator current of less than 10 mA for forward-acting controls.
· Actuator current greater than 180 mA for reverse-acting controls.
For controls with actuator current of 40 to 320 mA, minimum fuel is defined as:
· Actuator current of less than 20 mA for forward acting controls.
· Actuator current of more than 360 mA for reverse-acting controls.
A contact to override the failed-speed-signal circuit can be connected in series
with terminal 4 and low voltage dc power. (This power is available on terminal 2
for units supplied with 10 to 40 Vdc power and from terminal 6 on those units
supplied with about 120 V ac or dc power.) Temporarily closing the contact
overrides the failed-speed-signal circuit as required for start-up.
The control must be tuned to each system for optimum performance. The
potentiometers for setting and adjusting these circuits are located in the upper
right corner of the control as shown in Figure 4-2. They include:
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
9907-018
DSS-2
5464-643
5466-031
5466-253
5466-258
5466-348
5466-353
5501-367
5501-376
5464-658
5466-409
9907-838
9907-014
9905-131
9907-186
9907-414
9907-838
9970-164
5441-413
9905-003
505-4532
8200-224
1247-007
1326-183
1355-169
5210-543
5464-551
8250-565
8290-195
8405-307
8406-113
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020