All other units in the engine control system must be adjusted and working correctly before operating the synchronizer. While operating the engine to make
adjustments on the other units, the synchronizer mode switch (user supplied) must be in the OFF position.
Benefits:
Prime mover will
not accept full
load.
Is the governor at full
fuel?
YES—
1. Is the linkage adjusted properly?
2. Is load excessive?
3. Is the voltage regulator (if used) set properly?
4. Is the fuel stop on the prime mover set correctly?
NO—
1. Is the load limit out of the way, and adjusted properly?
2. Is the fuel limited (if so equipped) set too low?
3. Is there adequate air pressure for the fuel limiter?
4. Is the linkage sticky or improperly adjusted?
5. If electric start fuel limiter—is there adequate voltage for the
solenoid?
Needle valve
adjustment does
not eliminate
instability.
(1) Are the oscillations
periodic and smooth
(not intermittent)?
YES—
Go to question (2).
NO—
Check the following:
1. Is the fuel source adequate and constant?
2. Is the speed setting reference steady?
3. Is the governor oil level low?
4. Is the load erratic?
5. Is the governor oil clean?
(2) Is the frequency of
the oscillation above 5
Hz?
YES—
Check the following:
1. Governor drive train.
2. Governor alignment.
3. Dirty spring-driven oil damped ballhead (if so equipped).
4. Bad injector or misfire?
NO—
Go to question (3).
(3) Are the oscillations
related to speed setting
variations?
YES—
The cause of the speed setting variation must be found and
corrected.
NO—
Go to question (4).
(4) Does the oscillation
disappear when
blocking governor
output or operating
hand throttle?
YES—
1. Is linkage loose or worn?
2. Is governor part number correct for this application?
3. Replace governor.
NO—
1. Check for load fluctuations.
2. Check fuel supply.
3. Check for loose or sticky linkage.
When blocking governor output or operating the hand
throttle, the system is not under governor control, and
extreme caution must be taken to prevent overspeed. Do
not attempt if overspeed speed device is not functioning.
Governor will not
shut prime mover
down.
Is governor at minimum
fuel position?
YES—
Linkage is improperly set to allow shutdown.
NO—
1. Is shutdown actuation signal available at the governor?
2. Are shutdowns properly adjusted?
3. Is shutdown strap in governor properly adjusted?
4. Close off fuel and replace governor.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
9907-018
DSS-2
5464-643
5466-031
5466-253
5466-258
5466-348
5466-353
5501-367
5501-376
5464-658
5466-409
9907-838
9907-014
9905-131
9907-186
9907-414
9907-838
9970-164
5441-413
9905-003
505-4532
8200-224
1247-007
1326-183
1355-169
5210-543
5464-551
8250-565
8290-195
8405-307
8406-113
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020